Amorphous alloy dry-type transformer
SCBH15, SCBH17 и SCBH19
The SCBH series amorphous alloy dry-type transformers developed and designed by us are characterized by excellent performance, safety, reliability, energy conservation and environmental protection. They go deep into the load center and meet the needs of the development of modern big cities with high density loads.
These products have the advantages of fire resistance, self-extinguishing, moisture resistance, moisture resistance and crack resistance. They can be widely used in high-rise buildings, commercial centers, subways, airports, stations, industrial and mining enterprises and power plants. They are especially suitable for installation and use in places with high fire prevention requrements such as flammable and explosive places.
These products have the advantages of fire resistance, self-extinguishing, moisture resistance, moisture resistance and crack resistance. They can be widely used in high-rise buildings, commercial centers, subways, airports, stations, industrial and mining enterprises and power plants. They are especially suitable for installation and use in places with high fire prevention requrements such as flammable and explosive places.
Quantity
Product Features:
The iron core is made of coiled amorphous alloy strips. They adopt rectangular cross section and three-phase five-column structure or three-phase three-column structure. Their no-load loss is reduced by three quarters compared with that of ordinary dry-type transformers, showing remarkable energy saving effect.
The LV coil is wound with copper foil, and the HV coil is made of epoxy resin by vacuum casting. The products adopt a continuous structure and the baking and curing at high temperature. They have high mechanial strength, good heat dissipation effect and strong short circuit resistance.
They have fire resistance,explosion resistance, no pollution, high fire rating, low noise, small volume, easy installation, small partial discharge, high insulation level, and long service life.
Technicalparameters:
◆ Technical parameter table for SC(B)H15(NX3)Dry-type non-excitation voltage distribution transformer
Rated capacity (KVA) | voltage combination and tapping range | connection symbol | No-load current % | No-loadloss W | Load loss at different insulation levels W | ShortCircuit impedance % | ||||
High VoltageKV | HVtapping range % | Low voltage KV | 130℃(B) (100℃) | 155℃(F) (120℃) | 180℃(H) (145℃) | |||||
30 | 6 6.3 6.6 10 10.5 11 | ±5 ±2×2.5 | 0.4 | Yyn0 Dyn11 | 2.0 | 70 | 670 | 710 | 760 | 4.0 |
50 | 2.0 | 90 | 940 | 1000 | 1070 | |||||
80 | 1.5 | 120 | 1290 | 1380 | 1480 | |||||
100 | 1.5 | 130 | 1480 | 1570 | 1690 | |||||
125 | 1.3 | 150 | 1740 | 1850 | 1980 | |||||
160 | 1.3 | 170 | 2000 | 2130 | 2280 | |||||
200 | 1.1 | 200 | 2370 | 2530 | 2710 | |||||
250 | 1.1 | 230 | 2590 | 2760 | 2960 | |||||
315 | 1.0 | 280 | 3270 | 3470 | 3730 | |||||
400 | 1.0 | 310 | 3750 | 3990 | 4280 | |||||
500 | 1.0 | 360 | 4590 | 4880 | 5230 | |||||
630 | 0.85 | 420 | 5530 | 5880 | 6290 | |||||
630 | 0.85 | 410 | 5610 | 5960 | 6400 | 6.0 | ||||
800 | 0.85 | 480 | 6550 | 6960 | 7460 | |||||
1000 | 0.85 | 550 | 7650 | 8130 | 8760 | |||||
1250 | 0.85 | 650 | 9100 | 9690 | 10370 | |||||
1600 | 0.85 | 760 | 11050 | 11730 | 12580 | |||||
2000 | 0.70 | 1000 | 13600 | 14450 | 15560 | |||||
2500 | 0.70 | 1200 | 16150 | 17170 | 18450 | |||||
◆ Technical parameter table for SC(BH17(NX2) Dry-type non-excitation voltage distribution transformer
Rated capacity (KVA) | voltage combination and tapping range | connection symbol | No-load current % | No-loadloss W | Load loss at different insulation levels W | ShortCircuit impedance % | ||||
High VoltageKV | HV tapping range % | low voltageKV | 130℃(B) (100℃) | 155℃(F) (120℃) | 180℃(H) (145℃) | |||||
30 | 6 6.3 6.6 10 10.5 11 | ±5 ±2×2.5 | 0.4 | Yyn0 Dyn11 | 2.0 | 60 | 605 | 640 | 685 | 4.0 |
50 | 2.0 | 75 | 845 | 900 | 965 | |||||
80 | 1.5 | 100 | 1160 | 1240 | 1330 | |||||
100 | 1.5 | 110 | 1330 | 1415 | 1520 | |||||
125 | 1.3 | 130 | 1565 | 1665 | 1780 | |||||
160 | 1.3 | 145 | 1800 | 1915 | 2050 | |||||
200 | 1.1 | 170 | 2135 | 2275 | 2440 | |||||
250 | 1.1 | 195 | 2330 | 2485 | 2665 | |||||
315 | 1.0 | 235 | 2945 | 3125 | 3355 | |||||
400 | 1.0 | 265 | 3375 | 3590 | 3850 | |||||
500 | 1.0 | 305 | 4130 | 4390 | 4705 | |||||
630 | 0.85 | 360 | 4975 | 5290 | 5660 | |||||
630 | 0.85 | 350 | 5050 | 5365 | 5760 | 6.0 | ||||
800 | 0.85 | 410 | 5895 | 6265 | 6715 | |||||
1000 | 0.85 | 470 | 6885 | 7315 | 7885 | |||||
1250 | 0.85 | 550 | 8190 | 8720 | 9335 | |||||
1600 | 0.85 | 645 | 9945 | 10555 | 11320 | |||||
2000 | 0.70 | 850 | 12240 | 13005 | 14005 | |||||
2500 | 0.70 | 1020 | 14535 | 15445 | 16605 | |||||
◆ Technical parameter table for SC(B)H19(NX1) Dry-type non-excitation voltage distribution transformer
Rated capacity (KVA) | voltage combination and tapping range | connection symbol | No-load current % | No-loadloss W | Load loss at different insulation levels W | ShortCircuit impedance % | ||||
High VoltageKV | HV tapping range % | Low voltage KV | 130℃(B) (100℃) | 155℃(F) (120℃) | 180℃(H) (145℃) | |||||
30 | 6 6.3 6.6 10 10.5 11 | ±5 ±2×2.5 | 0.4 | Yyn0 Dyn11 | 2.0 | 50 | 605 | 640 | 685 | 4.0 |
50 | 2.0 | 60 | 845 | 900 | 965 | |||||
80 | 1.5 | 85 | 1160 | 1240 | 1330 | |||||
100 | 1.5 | 90 | 1330 | 1415 | 1520 | |||||
125 | 1.3 | 105 | 1565 | 1665 | 1780 | |||||
160 | 1.3 | 120 | 1800 | 1915 | 2050 | |||||
200 | 1.1 | 140 | 2135 | 2275 | 2440 | |||||
250 | 1.1 | 160 | 2330 | 2485 | 2665 | |||||
315 | 1.0 | 195 | 2945 | 3125 | 3355 | |||||
400 | 1.0 | 215 | 3375 | 3590 | 3850 | |||||
500 | 1.0 | 250 | 4130 | 4390 | 4705 | |||||
630 | 0.85 | 295 | 4975 | 5290 | 5660 | |||||
630 | 0.85 | 290 | 5050 | 5365 | 5760 | 6.0 | ||||
800 | 0.85 | 335 | 5895 | 6265 | 6715 | |||||
1000 | 0.85 | 385 | 6885 | 7315 | 7885 | |||||
1250 | 0.85 | 455 | 8190 | 8720 | 9335 | |||||
1600 | 0.85 | 530 | 9945 | 10555 | 11320 | |||||
2000 | 0.70 | 700 | 12240 | 13005 | 14005 | |||||
2500 | 0.70 | 840 | 14535 | 15445 | 16605 | |||||
amorphous alloy dry-type transformer,amorphous alloy transformerv,amorphous dry-type transformer,amorphous alloy distribution transformer,energy-saving dry-type transformer,low-loss dry-type transformer,amorphous alloy transformer manufacturer,amorphous alloy transformer price,amorphous alloy core transformer,new energy-saving transformer